  New types of AE Power substation equipment

72.5-kV Dry Air Insulated Dead Tank Type VCB

SF6-Gasless vacuum circuit breakers
 

We have developed and launched SF6 (sulfur hexafluoride) gas-less 72.5-kV class tank type vacuum circuit breakers. These circuit breakers are the first in the world in this voltage class to realize effective performance with no use of SF6 gas at all. SF6 gas has a high global warming coefficient. Although SF6 gas is harmless and stable, and has high electrical insulation ability, its global warming coefficient is about 23,900 times higher than that of CO2 (carbon dioxide). In 1997, a resolution to reduce the emissions of many kinds of greenhouse effect gas was adopted at the Kyoto conference (COP3). Since the conference, diminishing the emissions of SF6 gas has been an important matter in the world. Conventional vacuum circuit breakers use 0.15-Mpa SF6 gas. These vacuum circuit breakers use dry air pressurized to 0.45 Mpa and high-voltage electric conductors covered by certain insulated materials in order to achieve almost the same level of electrical insulation ability as that of conventional vacuum circuit breakers, as well as a compact structure. In addition, the circuit breakers use improved vacuum interrupters originally developed by us for withstanding high air pressure.


 
Other equipment
1.
Hybrid Molded Transformers
  A noise reducer is integrated into these molded transformers. As transformer capacity has recently been increasing, noise reduction is assuming more and more importance. Using the best coil structure and noise reducer (filter), we have developed large-capacity hybrid molded transformers (with a capacity of 10 kVA or more), which are in great demand.
Hybrid Molded Transformers
     
Vacuum Circuit Breakers with Permanent Magnetic Actuator
2.
7.2-kV class Vacuum Circuit Breakers with Permanent Magnetic Actuator
  The circuit breakers save space and energy and provide high performance to meet the needs of switchboard manufacturers. The circuit breakers, consisting of 80% fewer parts than conventional circuit breakers, are so small and light that they can be easily installed on a thin switchboard. They are the lightest of all circuit breakers of this class (the body weight is 20 kg).
     
3.
275-kV class Polymer Housed Arrester
  This arrester substitutes a composite housing (a high-strength fabric-reinforced plastic insulation pipe coated with highly water-repellent and weather-resistant silicone rubber) for a porcelain insulator. Moreover, it consists of alternately disposed larger-diameter and smaller-diameter fins to reduce the pitch between them. Because of these kinds of improvements, this arrester is by far smaller, lighter, and more quakeproof than conventional arresters.

 

Polymer Housed Arrester